RAID rebuild time

Q: Once I have assembled RAID 5 with 5 disks of 1.5 TB in NAS QNAP, disks started to synchronize. 20 hours have passed but only 57% is done. Is this normal? It seems that array works OK (I have already copied data to it) A: It is typical, especially if the array is also busy with copying data. For large arrays, first synchronization or a full rebuild (after drive replacement) often takes several days. It is advisable not to copy user data to the array until the first synchronization is complete because the array does not still provide redundancy and fault tolerance.

The most common problem with RAID5 is...

... that one does a rebuild with the wrong order of disks. This is by far the most common scenario we at www.FreeRaidRecovery.com have for an unrecoverable RAID 5. Something bad happens and the configuration is lost. The operator then assembles the array in a way which looks correct , and does a rebuild on it. The configuration which looks correct is just not good enough. You need a configuration which actually is correct. Doing a rebuild on a RAID 5 with wrong block size or disk order effectively destroys the data on the array. Theoretically, the data can still be restored, but practically the complexity of having two sets of parameters (with unknown block sizes, disk orders, and such) precludes any recovery.

Automatic recovery of RAID 5 with delayed parity

Recently we set to develop the algorithm to automatically recover RAID 5 array with delayed parity , as implemented by HP SmartArrays. Today we have mostly finalized the work. From this day on (build 306 onwards) ReclaiMe Free RAID Recovery is capable of recovering such arrays.

RAID 5 of two disks

The common wisdom says that RAID 5 requires a minimum of three disks. If one thinks of it, it is not true. You can create a RAID 5 of two disks. With even parity, the array becomes a mirror (RAID 1), and with odd parity (although nobody ever uses that), becomes a RAID 4 of two disks. And yes, the same applies to a RAID 4 of two disks.

Write hole in RAID 1

Actually, RAID 1 has the same write hole  problem as RAID 5 does. Should the power fail after one disk is updated, but the other is not yet updated, and then the first disk fails, there will be data corruption. As usual, scheduled synchronizations of the array reduce probability of this effect causing any practical trouble.

Exotic RAID types

With a RAID recovery , certain exotic RAID types can be recovered using the same basic algorithms, because these exotic RAID types can be reduced to one of the three basic types (RAID0, RAID1, and RAID5). The list goes like this: RAID 1+0 or 0+1 can either be reduced to RAID 0 by removing mirrors ( near layout), or can be recovered as a RAID 0 straight away ( far layout). RAID 5E or RAID 6E can be recovered as a RAID 5 or RAID 6 respectively, because all the extra data is at the end of the array. RAID 5EE can be recovered as RAID 6 with one of the sets of parity corrupt. RAID 4 is actually a variation of RAID 5 where parity does not change position across rows. The array types requiring special processing are RAID 1+0 using offset layout and RAID 1E.

Is RAID5 faster?

Is RAID5 faster than a single disk? On reads, yes. On writes, sometimes. On random writes, no. Check the RAID Calculator if you need similar data on RAID 0 or RAID 6.

RAID5 write hole

RAID 5 "write hole" happens if a power failure occurs during the write, causing an incomplete parity block update. The more detailed analysis of a "write hole" and its consequences is available at the RAID Recovery Guide .

RAID Tips Bonus - Unrecoverable Errors in RAID 5

There is a known issue with RAID 5 that if one drive in the array fails completely, then there may be a data loss during the rebuild if one of the remaining drives encounters an unrecoverable read error. These errors are relatively rare, but the size of arrays involved had increased to the point where one cannot even read the entire array without encountering a read error. There are some scary calculations available on the Internet (see an example here ), concluding that there is as much as 50% probability of failing the rebuild on the 12TB (6x2TB) RAID 5 if one disk fails. These calculations are based on somewhat naive assumptions, making the problem look worse than it actually is. First of all, the statement that " There is a 50% probability of being not able to rebuild a 12TB RAID 5 " is the same as " If you have a 10TB RAID 0 array, there is a 50% probability of not getting back what you write to it, if you write the data and then read it back immediately. " Tha...

RAID Tips 5 of 10 - Hot Spares

Hot spares are a good addition to a fault-tolerant array. If a drive has failed in a fault-tolerant (RAID 1 or RAID 5) array, there is a vulnerability window. If another drive fails during this vulnerability window, the data is lost. Hot spare drives allow the controller to rebuild the array without administrator intervention, thereby reducing the vulnerability window. The need for a hot spare increases as the number of disks in array increases. Hot spares are most effective when a single hot spare drive is shared between several arrays. Consider for example an 8-bay NAS. If there is only one RAID 5 array in the NAS, then RAID 6 may be a better option than a hot spare. The hot spare drive just sits there idly. In a RAID 6 array, the same drive would be utilized to improve a read speed. However if you need two RAID 5 arrays, the hot spare drive is shared between these two arrays, reducing the disk space overhead.

RAID Tips 4 of 10 - RAID 5 uncorrectable error probability

If you plan on building RAID 5 with a total capacity of more than 10 TB, consider RAID 6 instead. The problem with RAID 5 is that once the member disk had failed, it is required to read the entire array in order to complete the RAID rebuild. Although the probability of encountering a read error in any particular read operation is very low, the chance of a read error occurring increases as the array size increases. It has been widely speculated that the probability of encountering the read error during rebuild becomes practically significant as the array size approaches 10TB. Although the speculation relies on certain assumption which is not likely to be true (we'll have a writeup on that later), consider being better safe than sorry . RAID 6, being capable of correcting two simultaneous read errors, does not have this problem.

On RAID computational requirements

There is a widespread opinion that software RAID imposes significant processing power penalty on the host system, thereby decreasing overall performance. For a RAID 0, this is obviously not the case. The only overhead involved is to dispatch the sectors being read or written to their appropriate disk, requiring a fairly simple calculation once for every sector (512 bytes of data) written. RAID 5 and RAID 6 are more complicated. There is a requirement that parity data is computed for each write. However, the processing power requirements are modest and the resources are in abundance. Given the 100 MB/sec write speed, we need, say, 1,000 MIPS (Million Instructions Per Second) to calculate the parity. Also, there will be an additional memory bandwidth requirement of, say, 200 MB/sec (100 MB/sec in and out). Properly designed caching would alleviate the load even further. Still, a pretty modest CPU (made circa 2005) can provide about 15,000 MIPS and about 5,000 MB/sec memory bandwidth. So...

QNAP revisited

For reference, we were using QNAP TS-639 Pro with six WD20EADS disks. After about half a year of use, the web-interface was running slower, so that we needed to wait for several minutes to obtain the list of the disks. Gradually, we noted that the array performance decreased significantly. It seemed obvious to assume that one of the member disks has been dropped from the array and a RAID5 was working in the degraded mode. However, all the member disks were marked as GOOD in the web-interface. It was suspicious that LEDs on the disk bays indicating the state and activity of the disks were blinking unevenly. Logically, for RAID5 one should expect almost symmetric load on the disks, but in fact, one of the disk LED was blinking much more frequently. Once we had run the bad blocks check on this disk through the web-interface, the disk dropped from the array in less than half an hour and its bay LED turned red. At this point, the web-interface began to work properly again. The disk taken fr...

RAID5 diagram fail

Image
(Taken from WD site ) What's wrong with the picture? Select the whitespace below for an answer In the above RAID5 picture, there are two parities in the middle row. In a proper RAID5 there must be exactly one parity per row.